AM2 and AM2S Top Tips – S-Plan Heating System



As always preparing for your end skills test AM2, AM2S or AM2E requires time testing at college and in industry plus on-site experience of installing electrical circuits in order to pass your exam. This short video will help you remember to read the specification and think about selecting the correct size fuse for the s-plan heating system as stated in your specification during your end point assessment AM2 or AM2S.

This video has been designed to go on the YouTube shelf as a short video in portrait mode.

🔵 AM2, AM2S and AM2E Electrical Apprentices End Point Assessment

Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2 and 3.

You can follow me day by day on Facebook, Instagram, Twitter and TikTok lookout for “GSH Electrical”.

▶️ FACEBOOK

▶️ INSTAGRAM

▶️ TWITTER

▶️ TikTok

#GSHElectrical #Electricaltrainingvideos #shorts

source

9 Comments

  1. My specification didn't specify BUT it does say to the BS7671 Wirings Regulations, so if you read Reg 553.1.5 (i) it states "the connection of an eletric clock, provided that the plug and socket-outlet are designed specifically for that purpose, and that each plug incorporates a fuse of rating not exceeding 3 amperes complying with BS 646 or BS 1362 as appropriate." Obviously the programmer has an eletric clock so I took it that you need to use a 3AMP fuse.

    I found this after the exam but put a 3AMP fuse in cos I honestly couldn't sleep as I was pretty pissed off lol.

  2. I just did my AM2S and it did NOT specify the size of the fuse! I asked the assessor and he said “you are expected to know” I was so angry! Can’t believe it!

  3. As the S-plan controller is on the side wall and connected using PVC conduit. I found it easier to 1st use the fish tape to get my length, then cut I think 5 Brown 1.5mm2 (don't quote me on that) singles and with a sharpie identify each one with a simple ring on each conductor 1 ring, 2 rings and so on. This made it super fast when identifying end to end for final termination. I used brown, as the connections were a switched line, thus power transmission. READ THE SPEC!!!!

  4. Had heating engineer try to teach me. Gave me hard time for using 1mm, said it's on 3amp fuse. All the the rest using 2.5mm breaking the box's. Over sleaving the CPC. Don't let plumbers teach electrics.